APC Smart-UPS VT 40kVA 400V SUVTP40KH4B4S UPS Kenya

by Bosch

KES 1,450,000 Excl. Tax KES 2,000,000
Brand: APC by Schneider Electric
Model Number: SUVTP40KH4B4S
Output Power Capacity: 32kW / 40kVA
Max Configurable Power: 32kW / 40kVA
Nominal Output Voltage: 400V 3PH
Topology: Double Conversion Online
Output Connections: (1) Hard Wire 4-wire (3PH + G) (1) Hard Wire 5-wire (3PH + N + G) (1) Screw Terminals
Bypass: Built-in Maintenance Bypass Built-in Static Bypass
Input Connections: Hard Wire 5-wire (3PH + N + G)
Includes: Battery modules ship installed Bolt down brackets CD with software Installation guide Network Management Card Power modules ship installed Start up included User Manual
Price: Contact Sales
SKU13078

Reviews

This product does not have any reviews yet.

Add your review

Description

APC Smart-UPS VT 40kVA 400V SUVTP40KH4B4S UPS Kenya 

APC Smart-UPS VT 40kVA 400V SUVTP40KH4B4S UPS Kenya Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.

 

40kVA 400V SUVTP40KH4B4S UPS Gives higher application availability by correcting poor frequency and voltage conditions without using the battery. APC Smart-UPS VT 40kVA Enables pre-installation UPS staging and testing and faster installation.

 

APC Smart-UPS VT 40kVA Increases availability by allowing the UPS to be connected to two separate power sources. SUVTP40KH4B4S APC Smart-UPS VT 40kVA 400V w/4 Batt.

 

Mod., Start-Up 5X8, Internal Maint Bypass, Parallel Capability Battery modules ship installed , Bolt down brackets , CD with software , Installation guide , Network Management Card , Power modules ship installed , Start up included , User.

APC Smart-UPS VT 40kVA 400V w/4 Batt. Mod., Start-Up 5X8, Internal Maint Bypass, Parallel Capability

  • Parallel-capacity capable
    Increases total power capacity by using multiple uninterruptible power supplies simultaneously.
  • Parallel-redundant capable
    Power the connected equipment with multiple uninterruptible power supplies to increase system redundancy

Smart-UPS VT Features & Benefits

Availability
  • Battery modules connected in parallel
    Delivers higher availability through redundant batteries.
  • Automatic internal bypass
    Supplies utility power to the connected loads in the event of a UPS power overload or fault.
  • Dual mains input
    Increases availability by allowing the UPS to be connected to two separate power sources.
  • Generator compatible
    Ensures clean, uninterrupted power to protected equipment when generator power is used.
  • Scalable runtime
    Allows additional run time to be quickly added as needed.
Manageability
  • Programmable frequency
    Ensures compatibility with different input frequencies.
  • Audible alarms
    Provides notification of changing utility power and UPS power conditions
  • LCD display
    Alpha-Numeric Display which displays system parameters and alarms.
  • SmartSlot
    Customize UPS capabilities with management cards.
  • InfraStruXure Manager Compatible
    Enables centralized management via the APC InfraStruXure Manager.
  • Network manageable
    Provides remote power management of the UPS over the network.
  • LED status indicators
    Quickly understand unit and power status with visual indicators.
Total Cost of Ownership
  • Temperature-compensated battery charging
    Prolongs battery life by regulating the charge voltage according to battery temperature.
  • Manual maintenance bypass
    Reduces installation costs by eliminating the need for an external mechanical bypass.
  • Intelligent battery management
    Maximizes battery performance, life, and reliability through intelligent, precision charging.
  • Input power factor correction
    Minimizes installation costs by enabling the use of smaller generators and cabling.
Sustainability
  • EU CoC for UPS
    Ensures that UPSs sold in the EU are highly efficient
Protection
  • Cold-start capable
    Provides temporary battery power when the utility power is out.
  • Safety-agency approved
    Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
  • Frequency and voltage regulation
    Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Marketing Features
  • Hot-swappable batteries
    Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Input power factor correction
    Minimizes installation costs by enabling the use of smaller generators and cabling.
  • Dual mains input
    Increases availability by allowing the UPS to be connected to two separate power sources.
  • Scalable runtime
    Allows additional run time to be quickly added as needed.
  • Network manageable
    Provides remote power management of the UPS over the network.
  • Manual maintenance bypass
    Reduces installation costs by eliminating the need for an external mechanical bypass.
Serviceability
  • Modular design
    Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
  • Battery replacement without tools
    Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
  • Automatic self-test
    Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Shippable with modules installed
    Enables pre-installation UPS staging and testing and faster installation.

40kva UPS Battery Backup specifications

Output

  • Output Power Capacity: 32.0 KW / 40.0 kVA
  • Max Configurable Power (Watts): 32.0 KW / 40.0 kVA
  • Nominal Output Voltage: 400V 3PH
  • Output Voltage Note: Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
  • Efficiency at Full Load: 95.8 %
  • Output Voltage Distortion: Less than 5% at full load
  • Output Frequency (sync to mains): 47 - 53 Hz for 50 Hz nominal
  • Output Frequency (not synced): 50Hz +/- 0.1% for 50Hz nominal
  • Other Output Voltages: 380, 415
  • Crest Factor: 3 : 1
  • Topology: Double Conversion Online
  • Waveform Type: Sine wave
  • Maximum Output Current: 64
  • Bypass: Built-in Maintenance Bypass, Built-in Static Bypass

Input

  • Nominal Input Voltage: 400V 3PH
  • Input Frequency: 40- 70 Hz (auto sensing)
  • Input Connections: Hard Wire 5-wire (3PH + N + G)
  • Input voltage range for main operations: 304 - 477 V
  • Other Input Voltages: 380 , 415
  • Efficiency at Full Load: 95.8 %
  • Maximum Input Current: 55 A
  • Input Power Factor at Full Load: 0.98

Batteries & Runtime

  • Battery Type: VRLA
  • Included Battery Modules: 4
  • Typical recharge time: 5 hour(s)
  • Nominal Battery Voltage: +/-192 V (split battery referenced to neutral)
  • Expected Battery Life (years): 3 - 5
  • RBC Quantity: 4
  • Extendable Run Time: 1
  • End of Discharge Battery Voltage: +/-154 V

Communications & Management

  • Interface Port(s): DB-9 RS-232, Smart-Slot
  • Pre-Installed SmartSlot™ Cards: AP9631
  • Control panel: Multi-function LCD status and control console
  • Audible Alarm: Audible and visible alarms prioritized by severity
  • Emergency Power Off (EPO): Yes

Physical

  • Maximum Height: 1490.0 mm
  • Maximum Width: 523.0 mm
  • Maximum Depth: 842.0 mm
  • Net Weight: 629.09kg