Mecer ME-1000-WPTU UPS, 1KVA Pro Online Smart UPS

by mecer

KES 39,000 Excl. Tax
  • 1KVA/2KVA/3KVA/6KVA Available
  • True double-conversion
  • Wide input voltage range (110-300VAC)
  • Input power factor correction 0.98
  • Generator compatible
  • RS-232 communication port or mini slot for USB / RS-232 / AS400 /
  • SNMP communication
  • Smart battery charger design for optimized battery performance
UPCME-1000-WPTU UPS
Model Number1KVA UPS
SKU14487

Reviews

This product does not have any reviews yet.

Add your review

Description

Mecer ME-1000-WPTU 1KVA Pro Online Smart UPS 

Mecer ME-1000-WPTU 1KVA Pro Online Smart UPS from the leading mecer UPS authorised dealer, buy online ME-1000-WPTU 1KVA Pro Online Smart-UPS.

Power disruption and power surges can be very costly for every business,  with destruction to equipment to low production in a business resulting to fewer sales and poor customer satisfaction in case of service delivery organization thats why we recommend ,

Mecer 1KVA Online UPS Mtech networks is here to change that with Mecer 1KVA UPS that can help run small equipment up to 4 hours and also prevent them from being damaged by the power surge.

Mecer ME-1000-WPTU 1KVA Pro Online Smart UPS specifications

SKU ME-1000-WPTU
WEIGHT 9.8000
PHYSICAL DIMENSIONS 282 x 145 x 220 (mm)
CAPACITY 1000 VA / 800 W
VOLTAGE RANGE LOW LINE TRANSFER 160VAC/140VAC/120VAC/110VAC±5% ( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)
VOLTAGE RANGE LOW LINE COMEBACK 168VAC/148VAC/128VAC/118VAC ± 5 % ( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)
VOLTAGE RANGE HIGH LINE TRANSFER 300 VAC ± 5 %
VOLTAGE RANGE HIGH LINE COMEBACK 290 VAC ± 5 %
FREQUENCY RANGE 40Hz ~ 70 Hz
PHASE Single phase with ground
POWER FACTOR ? 0.99 @ nominal voltage (input voltage)
OUTPUT VOLTAGE 200/208/220/230/240VAC
AC VOLTAGE REGULATION (BATT. MODE) ±1% (Batt. Mode)
FREQUENCY RANGE (SYNCHRONIZED RANGE) 47 ~ 53 Hz or 57 ~ 63 Hz
FREQUENCY RANGE (BATT. MODE) 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
OVERLOAD Sounding twice every second
CURRENT CREST RATIO 3:1
HARMONIC DISTORTION ? 3 % THD (linear load) ? 6 % THD (non-linear load)
WAVEFORM (BATT. MODE) Pure Sinewave
AC TO DC Zero
INVERTER TO BYPASS 4 ms (Typical)
AC MODE 87%
BATTERY MODE 83%
BATTERY TYPE 12 V / 9 AH
NUMBERS 2
RECHARGE TIME 4 hours recover to 90% capacity (Typical)
CHARGING CURRENT 1.0 A (max.)
CHARGING VOLTAGE 27.4 VDC ± 1%
BATTERY TYPE & NUMBERS No
CHARGING CURRENT No
CHARGING VOLTAGE No
HUMIDITY 20-90 % RH @ 0- 40°C (non-condensing)
NOISE LEVEL Less than 50dBA @ 1 Meter
OPTIONAL USB/RS-232 PORT Supports Windows® 2000/2003/XP/Vista/2008/7, Linux, Unix and MAC
OPTIONAL SNMP Power management from SNMP manager and web browser

Run-times of ME-1000-WPTU 1kVA

Model Number of Batteries Encasement 100% Load Backup Time 75% Load Backup Time 50% Load Backup Time 25% Load Backup Time
ME-1000-WPTU 2 Internal 4 Minutes 6 Minutes 11 Minutes 24 Minutes