1X16 Bare PLC Steel Tube 250µm Single Mode Fiber Splitter
by Fiber
General Specifications
- Product Type: Planar Lightwave Circuit (PLC) Optical Splitter
- Configuration: 1x16 (1 input fiber and 16 output fibers)
- Design: Bare PLC Splitter in a Steel Tube
- Fiber Type: Singlemode Fiber
- Fiber Buffer Diameter: 250µm (tight-buffered)
Optical Performance
- Wavelength Range: 1260 nm - 1650 nm (supports both 1310 nm and 1550 nm windows)
- Insertion Loss:
- Typical: ≤ 12.0 dB
- Maximum: ≤ 13.0 dB
- Uniformity: ≤ 1.5 dB (ensures consistent signal distribution among outputs)
- Return Loss: ≥ 50 dB (minimizes back reflections)
- Directivity: ≥ 55 dB (reduces cross-talk between inputs and outputs)
- Polarization Dependent Loss (PDL): ≤ 0.2 dB (ensures consistent performance regardless of polarization)
- Splitting Ratio: 1:16 (equal power distribution)
Fiber Specifications
- Fiber Mode Compatibility: ITU-T G.657A or G.652D compliant
- Input/Output Fiber Diameter: 250µm tight-buffered fiber
- Cable Jacket Material: Steel tube for added protection and mechanical strength
Physical Dimensions
- Enclosure Type: Steel tube
- Dimensions:
- Length: Typically 60-100 mm (varies by design)
- Diameter: Approximately 6-8 mm
- Weight: Approximately 50-100 grams (varies by design and length)
Environmental Specifications
- Operating Temperature: -40°C to +85°C (suitable for a wide range of environments)
- Storage Temperature: -40°C to +85°C
- Humidity: 0% to 95% (non-condensing, suitable for various environmental conditions)
Installation Features
- Mounting: Typically installed in splice trays or enclosures
- Cable Management: Requires external cable management solutions
- Accessibility: Accessible for splicing and maintenance
- Labeling: Clear port numbering and labeling for easy identification and troubleshooting
Compliance and Standards
- Industry Standards:
- Telcordia GR-1209 and GR-1221 compliant for reliability and performance
- IEC 61753-1 compliant for fiber optic interconnecting devices
- RoHS compliant for environmental and safety regulations
Additional Features
- Design: Compact and durable steel tube design for robust protection
- Accessories: May include splice sleeves, protective caps, and installation instructions
- Reliability: High stability and reliability for various network applications, including FTTH, PON, and CATV
- Durability: Engineered for long-term operation with low maintenance requirements
Model Number | 1X16 Bare PLC |
---|---|
SKU | 15705 |
Reviews
This product does not have any reviews yet.
Add your reviewDescription
1X16 Bare PLC Steel Tube 250µm Single Mode Fiber Splitter
1X16 Bare PLC Steel Tube 250µm Single Mode Fiber Splitter from the leading fiber dealer in Nairobi Kenya, buy 1X16 Bare PLC Steel Tube 250µm Single Mode Fiber Splitter and have it delivered.
PLC splitter is a type of optical power management device that is fabricated using silica optical waveguide technology to distribute optical signals from Central Office (CO) to multiple premise locations. 1X16 Bare PLC Steel Tube 250µm Single Mode Fiber is a kind of ODN product suitable for PON networks that can be installed in the pigtail cassette, test instrument and WDM system, which minimizes the space occupation.
1X16 Bare PLC Steel Tube 250µm Single Mode Fiber is relatively fragile on fiber protection and need a complete protection design on carrying box body and device.
Name of the test
|
Condition
|
Duration
|
Temperature- Humidity aging
|
85°C and 85% RH
|
7 days
|
Vibration
|
10 - 55Hz, 1.52mm double amplitude, in three axes
|
1 hour
|
Component Impact
|
Test Impact of 500g (mass ? 0.125kg), 1ms , half sine pulse
|
2 impacts
|
Temperature Cycling Test
|
-40 - 70°C, Ramp rate: 1°C /min, Dwell time > 15min
|
10 cycles
|
Temperature- Humidity cycling
|
-40 - 85°C , between 10°C and 23°C - 85% RH, at 85°C - 20%RH, between °C and 85°C - maintain a linear change in RH, below 10°C - uncontrolled RH
|
14 days
|
Water Immersion
|
43 ± 2°C , PH 5.5 ± 0.5
|
7 days
|
Fiber Side Pull test
|
0.23 kg load, 90° angle , 2 directions
|
5 seconds
|
Fiber Side Pull test
|
0.45 Kg load for Single Input Fiber, 1.5 Kg load for 8 Fiber Ribbon Outputs
|