Mecer 10KVA 3 Phase Online Smart UPS
by mecer
- 3kVA / 2400 Watt
- Internal Batteries
- Plug and Play High Frequency UPS
- On-Line Topology with built in bypass
UPC | ME-10000-GT 10KVA |
---|---|
Model Number | 10kva UPS |
SKU | 14504 |
Reviews
This product does not have any reviews yet.
Add your reviewDescription
Mecer 10KVA 3 Phase Online Smart UPS
Mecer 10KVA 3 Phase Online Smart UPS from the leading mecer UPS dealer in Nairobi Kenya, buy online and have it delivered, 10KVA 3 Phase Online Smart UPS.
Mecer 10KVA 3 Phase Online UPS is a high frequency unit specifically designed for servers, data-center critical network devices, sensitive electronic equipment, telecom, banks, hospitals etc.
SKU | ME-3000-WPTU |
---|---|
WEIGHT | 27.600 |
PHYSICAL DIMENSIONS | 421 x 190 x 318 (mm) |
CAPACITY | 3000 VA / 2400 W |
VOLTAGE RANGE LOW LINE TRANSFER | 160VAC/140VAC/120VAC/110VAC±5% ( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0) |
VOLTAGE RANGE LOW LINE COMEBACK | 168VAC/148VAC/128VAC/118VAC ± 5 % ( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0) |
VOLTAGE RANGE HIGH LINE TRANSFER | 300 VAC ± 5 % |
VOLTAGE RANGE HIGH LINE COMEBACK | 290 VAC ± 5 % |
FREQUENCY RANGE | 40Hz ~ 70 Hz |
PHASE | Single phase with ground |
POWER FACTOR | ? 0.99 @ nominal voltage (input voltage) |
OUTPUT VOLTAGE | 200/208/220/230/240VAC |
AC VOLTAGE REGULATION (BATT. MODE) | ±1% (Batt. Mode) |
FREQUENCY RANGE (SYNCHRONIZED RANGE) | 47 ~ 53 Hz or 57 ~ 63 Hz |
FREQUENCY RANGE (BATT. MODE) | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz |
OVERLOAD | Sounding twice every second |
CURRENT CREST RATIO | 3:1 |
HARMONIC DISTORTION | ? 3 % THD (linear load) ? 6 % THD (non-linear load) |
WAVEFORM (BATT. MODE) | Pure Sinewave |
AC TO DC | Zero |
INVERTER TO BYPASS | 4 ms (Typical) |
AC MODE | 90% |
BATTERY MODE | 88% |
BATTERY TYPE | 12 V / 9 AH |
NUMBERS | 6 |
RECHARGE TIME | 4 hours recover to 90% capacity (Typical) |
CHARGING CURRENT | 1.0 A (max.) |
CHARGING VOLTAGE | 82.1 VDC ± 1% |
BATTERY TYPE & NUMBERS | No |
CHARGING CURRENT | No |
CHARGING VOLTAGE | No |
HUMIDITY | 20-90 % RH @ 0- 40°C (non-condensing) |
NOISE LEVEL | Less than 50dBA @ 1 Meter |
OPTIONAL USB/RS-232 PORT | Supports Windows® 2000/2003/XP/Vista/2008/7, Linux, Unix and MAC |
OPTIONAL SNMP | Power management from SNMP manager and web browser |
Run-times of ME-3000-WPTU 3kVA
Model | Number of Batteries | Encasement | 100% Load Backup Time | 75% Load Backup Time | 50% Load Backup Time | 25% Load Backup Time |
ME-3000-WPTU | 6 | Internal | 4.5 Minutes | 7 Minutes | 13 Minutes | 31 Minutes |
Online-Double conversion Supports all kinds of load, high overload capability Fully digitally controlled with 3 DSPs for IGBT rectifier, inverter and battery charger Digital Circulating Current Control Technology, Increasing Parallel Reliability Green Power Technology, High Input Power Factor, Low Current THD, High Efficiency Intellegent self-diagnosis function, All kinds of fault protection, Large event log capability Redundant Design of Power Model Fans, Increasing system reliability High MTBF (Mean Time Between Failures) (>200,000 HOURS), Low MTTR (Mean Time To Repair