Mecer 1KVA Smart UPS Rack Mount
by mecer
- 4 hours battery recharge time
- 12V / 9AH battery
- 1 USB port
- 240Volt output voltage
- 800 watt maximum load
- Converter mode available
- ECO mode for energy saving
- Output power factor 0.8
Model Number | ME-1000GRU |
---|---|
SKU | 642 |
Reviews
This product does not have any reviews yet.
Add your reviewDescription
Mecer 1KVA Smart-UPS Rack Mount
Mecer 1KVA Online UPS is designed for performers, 10KVA online UPS keeps the user working even when there is no power, we all know Kenya power is not reliable anyway.
Mecer 1KVA UPS has a lead time of more than 30 minutes hence the user will have adequate time to finish any unfished task. 1KVA mecer online UPS has a screen that helps the user to monitor the performance of the UPS, when on, off and the current status of the batteries. Mecer 1KVA smart UPS is rack-mountable hence it can be mounted in the server rack.
being mounted in a server rack increases the shelf life of the UPS as well as it security since the server rack would be under lock. Power disruption and power surges can be very costly for every business, with destruction to equipment to low production in a business resulting to fewer sales and poor customer satisfaction in case of service delivery organization that's why we recommend .
Mecer 1KVA Online UPS Mtech networks is here to change that with Mecer 1KVA UPS that can help run small equipment up to 4 hours and also prevent them from being damaged by the power surge.
Mecer 1KVA smart UPS specifications
SKU | ME-1000-WPTU |
---|---|
WEIGHT | 9.8000 |
PHYSICAL DIMENSIONS | 282 x 145 x 220 (mm) |
CAPACITY | 1000 VA / 800 W |
VOLTAGE RANGE LOW LINE TRANSFER | 160VAC/140VAC/120VAC/110VAC±5% ( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0) |
VOLTAGE RANGE LOW LINE COMEBACK | 168VAC/148VAC/128VAC/118VAC ± 5 % ( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0) |
VOLTAGE RANGE HIGH LINE TRANSFER | 300 VAC ± 5 % |
VOLTAGE RANGE HIGH LINE COMEBACK | 290 VAC ± 5 % |
FREQUENCY RANGE | 40Hz ~ 70 Hz |
PHASE | Single phase with ground |
POWER FACTOR | ? 0.99 @ nominal voltage (input voltage) |
OUTPUT VOLTAGE | 200/208/220/230/240VAC |
AC VOLTAGE REGULATION (BATT. MODE) | ±1% (Batt. Mode) |
FREQUENCY RANGE (SYNCHRONIZED RANGE) | 47 ~ 53 Hz or 57 ~ 63 Hz |
FREQUENCY RANGE (BATT. MODE) | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz |
OVERLOAD | Sounding twice every second |
CURRENT CREST RATIO | 3:1 |
HARMONIC DISTORTION | ? 3 % THD (linear load) ? 6 % THD (non-linear load) |
WAVEFORM (BATT. MODE) | Pure Sinewave |
AC TO DC | Zero |
INVERTER TO BYPASS | 4 ms (Typical) |
AC MODE | 87% |
BATTERY MODE | 83% |
BATTERY TYPE | 12 V / 9 AH |
NUMBERS | 2 |
RECHARGE TIME | 4 hours recover to 90% capacity (Typical) |
CHARGING CURRENT | 1.0 A (max.) |
CHARGING VOLTAGE | 27.4 VDC ± 1% |
BATTERY TYPE & NUMBERS | No |
CHARGING CURRENT | No |
CHARGING VOLTAGE | No |
HUMIDITY | 20-90 % RH @ 0- 40°C (non-condensing) |
NOISE LEVEL | Less than 50dBA @ 1 Meter |
OPTIONAL USB/RS-232 PORT | Supports Windows® 2000/2003/XP/Vista/2008/7, Linux, Unix and MAC |
OPTIONAL SNMP | Power management from SNMP manager and web browser |
Run-times of ME-1000-WPTU 1kVA
Model | Number of Batteries | Encasement | 100% Load Backup Time | 75% Load Backup Time | 50% Load Backup Time | 25% Load Backup Time |
ME-1000-WPTU | 2 | Internal | 4 Minutes | 6 Minutes | 11 Minutes | 24 Minutes |