Mercury 2KVA Line-interactive UPS, 2000KVA UPS
by MERCURY
- Capacity: 2KVA / 1400W; Single Phase
- Technology: High frequency & double conversion on-line
- Fully digitized microprocessor control
- Wide input voltage range: 115VAC(±5) ~ 295VAC(±5) if load ? 70%
- LCD display
- UPS startup without battery
- Cold start
- Advanced battery management
- Automatic battery charge in UPS off mode
- Lightning & surge protection
- Short circuit & overload protection
- Fan speed auto control when load varies
- Network/Fax/Modem surge protection
- Optional extension battery pack
- Battery voltage & Load capacity display
- Smart RS232 communication with monitoring software
- Optional SNMP Card slot
- Input L and N reversed alarm function
Model Number | 2000KVA UPS |
---|---|
SKU | 11656 |
Reviews
This product does not have any reviews yet.
Add your reviewDescription
Mercury 2KVA Line-interactive UPS
Mercury 2KVA Line-interactive UPS is designed for your sensitive equipment where zero tolerance for break in power supply is imperative, 2KV Mercury UPS not only provides the required power backup but also ensures zero switch-over time to prevent service disruption.
Mercury 2000VA UPS provides perfect balance between top performance, reliability and budget-friendly pricing, the Mercury online UPS range has an outstanding rating. With the Mercury 2kva UPS, you get that high-rated performance from a 1400 W capacity UPS.
Mercury 2KVA Line-interactive UPS ( 2000KVA UPS ) has a rated capacity of 1400W, the Mercury 2KVA UPS can support multiple office devices. It will deliver up to 19 minutes power backup at half load and some 8 minutes backup at full load. Powered by 3x 7AH battery, the Mercury 2KVA online UPS meets the backup requirement for most small office appliances.
SPECIFICATIONS OF MERCURY 2KVA UPS
Here are the specs:
Capacity | 2KVA / 1400W |
Phase | Single Phase |
Input voltage | 115VAC(±5) ~ 295VAC(±5) if load ? 70%; 160VAC(±5) ~ 295VAC(±5) if load ? 70% |
Frequency | 46 ~ 54±0.5Hz; 56 ~ 64±0.5Hz auto sensing |
Input power factor | 0.97 |
Output voltage | 220/230VAC ± 2% |
Frequency | 50Hz / 60Hz ± 0.2% |
THD | < 3% (linear load); < 6% (non linear load) |
Overload capability | > 110%, 30s turn to bypass mode; > 150%, 300ms turn to bypass mode |
Crest factor | 3:1 (max) |
Short circuit protection | 5 cycles turn off inverter, no transfer tp bypass, provide alarm (AC mode); 5 cycles turn off inverter, provide alarm (AC mode); Unput fuse blown or breaker action (bypass mode) |
Waveform | Pure sine wave |
Transfer time | 0ms between AC mode & Bypass mode 4ms (typical 2.5ms) between Inverter mode & Bypass mode |
Efficiency | 85% |
Model | 12V sealed lead acid maintenance free |
Battery | 8x 12V / 7AH |
DC voltage | 96VDC |
Back-up | 19min (half load); 8min (full load) |
Recharge time | 8hours ~ 90% capacity |
Charge current | 1A(standard unit);6A(long time unit) |
Communication interface | RS232 ; SNMP (optional) |
LED indication | Load or battery capacity |
Noise level | < 45dB |
Temperature | 0 ~ 40?C |
Humidity | 0% ~ 95% (non-condensing) |
Altitude | < 1500m |
Storage temperature | -25 ~ 55?C |
Standard unit (net/gross) | 33 / 35kg |
Long time unit (net/gross) | 14 / 16kg |
Dimension (WxDxH)mm | 191 x 478 x 339mm |
Packing(WxDxH)mm | 332 x 603 x 482mm |