Mercury 2KVA Online smart UPS, HP920C-S 0.8PF

by MERCURY

KES 80,000 Excl. Tax KES 82,000
  • Model: Mercury HP920C-S
  • Type: Online Double Conversion UPS
  • Topology: True Online Double Conversion
  • Form Factor: Tower

Capacity:

  • Power Capacity: 2000VA / 1600W
  • Power Factor: 0.8
UPCHP920C-S 0.8PF
Model Numbermercury 2kva
Capacity 2KVA UPS
Type smart online
Layout Tower UPS
SKU0200303003003

Reviews

This product does not have any reviews yet.

Add your review

Description

Mercury 2KVA Online smart UPS, HP920C-S 0.8PF

  • Model: Mercury HP920C-S
  • Type: Online Double Conversion UPS
  • Topology: True Online Double Conversion
  • Form Factor: Tower

Capacity:

  • Power Capacity: 2000VA / 1600W
  • Power Factor: 0.8

Input Specifications:

  • Input Voltage Range: 110V – 300V AC (depending on load)
  • Input Frequency: 40Hz – 70Hz (Auto Sensing)
  • Input Phase: Single-phase with ground
  • Input Power Factor: ≥ 0.99 (at full load)

Output Specifications:

  • Output Voltage: 220/230/240V AC (Selectable)
  • Output Frequency: 50Hz / 60Hz (Auto Sensing)
  • Output Waveform: Pure Sine Wave
  • Voltage Regulation: ± 1%
  • Transfer Time: Zero (Online Double Conversion)
  • Crest Factor: 3:1

Battery:

  • Battery Type: Sealed Lead-Acid Maintenance-Free
  • Battery Voltage: 48V DC
  • Backup Time: Depends on load (e.g., approximately 5-10 minutes at full load)
  • Recharge Time: 4-6 hours to 90% capacity
  • Battery Management: Intelligent Battery Management (including overcharge and deep discharge protection)

Features:

  • LCD Display: Yes (displays input/output voltage, frequency, load level, battery level, and other status indicators)
  • Audible Alarm: Yes (overload, battery low, fault)
  • Communication Ports: USB, RS232, SNMP (optional)
  • ECO Mode: Yes (energy-saving mode)
  • Cold Start Function: Yes (can start the UPS without utility power)
  • Auto Restart: Yes (automatically restarts the UPS when AC power is restored)

Protection:

  • Overload Protection: Yes
  • Short Circuit Protection: Yes
  • Surge Protection: Yes
  • Overcharge Protection: Yes
  • Deep Discharge Protection: Yes
  • Input/Output Isolation: Yes (electrical noise isolation)

Physical Specifications:

  • Dimensions (W x D x H): Approximately 145 x 400 x 220 mm
  • Weight: Approximately 13 kg (may vary slightly based on battery configuration)

Environmental:

  • Operating Temperature: 0°C – 40°C
  • Operating Humidity: 0% – 95% RH (non-condensing)
  • Storage Temperature: -15°C – 50°C

Certifications:

  • Safety Compliance: CE, ISO 9001

Additional Features:

  • Hot-swappable Batteries: Yes
  • Bypass Mode: Automatic Bypass
  • Remote Monitoring: Optional via SNMP (requires additional SNMP card)
  • Noise Level: < 50dB at 1 meter
  •