by SECOLINK
Number of wired zones on the board: 5; Maximum number of zones: 7; Number of PGM outputs on the board: 1; Maximum number of PGM outputs: 3; Number of user codes: 5; User Code Recovery: Yes; Key-switch zone: Yes; Areas: 1; Number of timers in the system: 16; Volume of the event log: In the control panel - 256, in the set with keyboard
SKU | 12413 |
---|
Reviews
This product does not have any reviews yet.
Add your reviewDescription
Secolink GSV4B Kit
Secolink GSV4B Kit Economy class alarm system for small real estate objects. Supports up to 7 zones (5 zones on control panels board and 2 on keypad). Kit includes control panel GSV4B. GSM/GPRS communicator, keypad KM20B and fireproof, plastic case CAS6 with integrated transformer. Alarm system available only as a kit.
Features | GSV4B |
Description | Control panel with integrated GSM/GPRS module |
In-built wired zones on board | 5 |
Maximum wired zones | 7 |
PGM on board | 1 |
Maximum PGM | 3 |
User codes | 5 |
Defaulting user code | Yes |
Key switch zone | Yes |
Partitions | 1 |
System timers | 16 |
Event log size | 256 (with keypad 512) |
Data bus protocol | KRBUS |
Reporting to CMS format | CID via GPRS |
Total number of protocols, used for CMS reporting | E2 (Enigma), FIBRO (Sur-gard), CSV (Patriot), SIA |
Compatible with SG-SYSTEM II, III IP card | Yes |
Alarm message for end user | GSM calls, SMS |
Alarm message for end user by voice clip | Yes |
Recordable audio alarm messages | Yes |
Available language for SMS | English, National |
Remote system control by Android or IPhone application | Yes |
Zone speed (sensitivity) | 0.1 - 2.5 sec. |
Zone loop (detector) type | NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL |
Arming mode | Away, Max Away, Night, Stay. |
Zone definition | Entry/exit, entry/exit forced, interior, interior night armed, follower, interior night follower, perimeter, instant, PGM control; 24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature. |
Zone attributes | Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm, armed night. |
PGM definition | Fire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, wxit arm status, full arm status, arm/disarm acknowledge, power supply, resettable power supply, fire power supply, timer, mono/bi switch. |
PGM attributes | Inversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, arm notification, disarm notification, clear alarm notification. |
Rated voltage of power supply (AC) | ~20 V |
Minimum AC voltage | ~16 V |
Maximum AC voltage (Note: higher than ~22 V voltage can damage GSV4) | ~22 V |
Maximum long term output current of GSV4 (I+AUX + I+BELL + battery charge) | 0.7 A |
Maximum current of slow blowing fuse used in primary AC | 250 mA |
Maximum AC power consumption | <30 mA |
Minimum voltage on +AUX, +BELL, outputs | 12 V |
Maximum voltage on +AUX, +BELL, outputs | 13.9 V |
Maximum current out of +AUX | 0.25 A |
Maximum current out of +BELL (without battery) | 0.2 A |
Maximum current out of +BELL (with battery) | 2 A |
Short circuit, overload protection of +BELL, +AUX | electronic |
Battery charge +BELL, +AUX current measurement | Yes |
Failed (waste) backup battery disconnection | Yes |
Maximum battery charging current | 0.25 A |
Maximum current of fast blowing fuse used in battery | 3.15 A |
GSV4 disconnects battery when its voltage less than | 9.5 V |
Recommended backup power supply | 12 V, 7 Ah / 20 Hr |
Operational compliance | EN50131, Grade2 |
Overall dimensions W x H in mm | 120 x 64 |
Environmental compliance | ROHS |
Operating temperature | From -10oC to +50oC |
Interface for control panel settings programming | USB |
Interface for control panel firmware update | USB |
Remote control panel settings programming | Yes, via www.alarmserver.net |
Features | KM20B |
Description | Alarm system keypad |
On-Board zones | 2 |
On-Board PGM | - |
Ambient temperature measurement | - |
LCD type | 2 rows, 16 symbols each |
Keys in keypad | 20 |
Programmable fast keys (F-Keys) | 32 |
Data bus protocol | KRBUS |
Zone loop (detector) type | NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL |
Maximum wiring distance to CP | 300 m |
Power supply | 9 - 14 V |
Voltage measurement on keypad | Yes |
Current consumption | Backlight on 100 mA, baclight off < 50 mA. |
On-Board sounder | Buzzer |
Backlight color | Display = blue, keypad = yellow |
Character set | Latin, Russian, Greek, East European, West European, Azeri, Turkish, Scandinavian. |
User interface type | Advanced, Simple, Baltic, Asian. |
Overall dimensions W x H in mm | 115 x 95 |
Environmental compliance | ROHS |
Operating temperature | 0oC up to +50oC |
Interface for keypad settings programming | USB |
Interface for keypad firmware updating | USB |
Features |