Description |
Control panel with integrated GSM/GPRS module |
In-built wired zones on board |
5 |
Maximum wired zones |
7 |
PGM on board |
1 |
Maximum PGM |
3 |
User codes |
5 |
Defaulting user code |
Yes |
Key switch zone |
Yes |
Partitions |
1 |
System timers |
16 |
Event log size |
256 (with keypad 512) |
Data bus protocol |
KRBUS |
Reporting to CMS format |
CID via GPRS |
Total number of protocols, used for CMS reporting |
E2 (Enigma), FIBRO (Sur-gard), CSV (Patriot), SIA |
Compatible with SG-SYSTEM II, III IP card |
Yes |
Alarm message for end user |
GSM calls, SMS |
Alarm message for end user by voice clip |
Yes |
Recordable audio alarm messages |
Yes |
Available language for SMS |
English, National |
Remote system control by Android or IPhone application |
Yes |
Zone speed (sensitivity) |
0.1 - 2.5 sec. |
Zone loop (detector) type |
NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL |
Arming mode |
Away, Max Away, Night, Stay. |
Zone definition |
Entry/exit, entry/exit forced, interior, interior night armed, follower, interior night follower, perimeter, instant, PGM control; 24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature. |
Zone attributes |
Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm, armed night. |
PGM definition |
Fire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, wxit arm status, full arm status, arm/disarm acknowledge, power supply, resettable power supply, fire power supply, timer, mono/bi switch. |
PGM attributes |
Inversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, arm notification, disarm notification, clear alarm notification. |
Rated voltage of power supply (AC) |
~20 V |
Minimum AC voltage |
~16 V |
Maximum AC voltage (Note: higher than ~22 V voltage can damage GSV4) |
~22 V |
Maximum long term output current of GSV4 (I+AUX + I+BELL + battery charge) |
0.7 A |
Maximum current of slow blowing fuse used in primary AC |
250 mA |
Maximum AC power consumption |
<30 mA |
Minimum voltage on +AUX, +BELL, outputs |
12 V |
Maximum voltage on +AUX, +BELL, outputs |
13.9 V |
Maximum current out of +AUX |
0.25 A |
Maximum current out of +BELL (without battery) |
0.2 A |
Maximum current out of +BELL (with battery) |
2 A |
Short circuit, overload protection of +BELL, +AUX |
electronic |
Battery charge +BELL, +AUX current measurement |
Yes |
Failed (waste) backup battery disconnection |
Yes |
Maximum battery charging current |
0.25 A |
Maximum current of fast blowing fuse used in battery |
3.15 A |
GSV4 disconnects battery when its voltage less than |
9.5 V |
Recommended backup power supply |
12 V, 7 Ah / 20 Hr |
Operational compliance |
EN50131, Grade2 |
Overall dimensions W x H in mm |
120 x 64 |
Environmental compliance |
ROHS |
Operating temperature |
From -10oC to +50oC |
Interface for control panel settings programming |
USB |
Interface for control panel firmware update |
USB |
Remote control panel settings programming |
Yes, via www.alarmserver.net |