Secolink Intruder alarm panel PAS series

by SECOLINK

KES 23,000 Excl. Tax KES 25,000

Fire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, exit/arm status, full arm status, power supply, resettable power supply, fire power supply, timer, mono/bi switch

SKU12383

Reviews

Leave a product review
or cancel

Description

Secolink Intruder alarm panel PAS series 

Secolink Intruder alarm panel PAS series are designed for small businesses and individual property protection. Currently, these models are being manufactured: PAS808M, PAS816, PAS832, P16, P32, P64  that control 8, 16, 32, 64 intrusion detection sensors (zones), respectively. Secolink Intruder alarm panel models can protect up to 4 partitions (areas) and, depending on the model of the panel, (minus panels) can be controlled by 5 or up to 31 users.

More technical information can be found by clicking on the left side menu bar "Control panels". Secolink Intruder alarm panel Performs all necessary functions and is suited for the protection of apartments and offices. This control panel is supplemented with a function of calling user's phone. More technical information can be found in the table below.

Features PAS808M PAS816 PAS832
Alarm system concept Wired modular system Wired modular system Wired modular system
On-board wired zones 8 8/16 (doubling) 8/16 (doubling)
2-wire smoke detector input - - -
On-board wireless zones - - -
Maximum zones in system 8 16 32
On-board PGM 3 3 3
Maximum PGM in system 8 16 16
User + installer codes 5+1 31+1 31+1
Duress code X1, X2, X3, X4 (when X4 = X4 + 1)
Defaulting user code Yes Yes Yes
Key switch zone - Yes Yes
Partitions 4 4 4
"Shared" partition (common area) - Yes Yes
System timers - 16 16
Maximum keypads/modules in system 7 15 15
Event log buffer 512 512 512
PSTN communicator In-built In-built In-built
In-built interface for backup communicator TTL Serial TTL Serial TTL Serial
Data bus protocol KRBUS KRBUS KRBUS
Total phone numbers: CMS reporting + personal dialing 4 4 4
Maximum phone numbers for personal dialing Up to 4 Up to 4 Up to 4
Maximum phone numbers for CMS reporting Up to 4 Up to 4 Up to 4
Reporting protocol Contact ID Contact ID, 4x2 Contact ID, 4x2
Voice guide for system control over PSTN - PAS816 V3 only PAS832 V3 only
Voice guide for system programming over PSTN - PAS816 V3 only PAS816 V3 only
"Roller" detector type - Yes Yes
"Vibration" detector type Yes Yes Yes
"Vibration" zone speed (sensitivity) 0.01 - 0.25 sec. 0.01 - 0.25 sec. 0.01 - 0.25 sec.
Normal zone speed (sensitivity) 0.1 - 2.5 sec. 0.1 - 2.5 sec. 0.1 - 2.5 sec.
Zone loop (detector) type NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Vibration NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Vibration, Roller
Arming mode Away, Max Away, Night, Stay.
Zone definition Entry/exit, entry/exit forced, interior, interior night armed, follower, interior night follower, perimeter, instant, PGM control; 24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature
Zone attributes Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm, armed night
PGM definition Fire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, exit/arm status, full arm status, power supply, resettable power supply, fire power supply, timer, mono/bi switch
PGM attributes Inversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, disarm notification, clear alarm notification
Rated voltage of power supply (AC) ~20 V ~20 V ~20 V
Minimum AC voltage (note: ~16 V input voltage lets control panel to generate max 0.7 A output current) ~16 V ~16 V ~16 V
Maximum AC voltage (Note: higher than ~22 V voltage can damage control panel) ~22 V ~22 V ~22 V
Maximum long term output current of control panel (I+AUX + I+BELL + I+PGM + battery charge): ?1.2 A ?1.5 A ?1.5 A
Maximum current of slow blowing fuse used in primary AC 250 mA 250 mA 250 mA
Maximum AC power consumption 150 mA 150 mA 150 mA
Minimum voltage on +AUX, +BELL, +PGM outputs 12 V 12 V 12 V
Maximum voltage on +AUX, +BELL, +PGM outputs 13.9 V 13.9 V 13.9 V
Maximum current out of +AUX +0.8 A +1 A +1 A
Maximum current out of +BELL +0.8 A +2 A +2 A
Maximum current into -PGM -0.05 A -0.05 A -0.05 A
Maximum current out of +PGM +0.8 A +0.9 A +0.9 A
Short circuit, overload protection of +BELL, +PGM, +AUX Electronic Electronic Electronic
Battery charge, +BELL, +AUX current measurement - Yes Yes
Failed (waste) backup battery disconnection - Yes Yes
Maximum battery charging current +0.4 A +0.4 A +0.4 A
Maximum current of fast blowing fuse used in battery circuit 3.15 A 3.15 A 3.15 A
Control panel disconnect battery when it’s voltage less than 9.5 V 9.5 V 9.5 V
Recommended backup battery 12 V, 7 Ah / 20 Hr 12 V, 7 Ah / 20 Hr 12 V, 7 Ah / 20 Hr
Operational compliance +EN50131, Grade2 +EN50131, Grade2 +EN50131, Grade2
Overall dimensions W x H in mm 145 x 77 145 x 77 145 x 77
Environmental compliance ROHS ROHS ROHS
Operating temperature -10oC up to +50oC
Production status In production V2 discontinued, V3 in production V2 discontinued, V3 in production
Latest firmware version v0.03