Tripp Lite 2200VA SmartPro 230V 2.2kVA 1.6kW Line Interactive UPS Tower
Trip Lite 2200VA SmartPro 230V 2.2kVA 1.6kW Line Interactive UPS Tower from the leading UPS dealer in Nairobi Kenya, buy online Trip Lite 2200VA SmartPro 230V 2.2kVA 1.6kW Line Interactive UPS Tower and have it delivered Tripp Lite's SMARTINT2200VS intelligent, line interactive tower uninterruptible power supply (UPS) prevents data loss, downtime and equipment damage due to power outages, voltage fluctuations and transient surges.
Tripp Lite 2200VA SmartPro 230V 2.2kVA 1.6kW Line Interactive UPS Tower Large internal batteries offer 19 minutes half load runtime and 7 minutes at full load. Tripp Lite 2200VA SmartPro 230V 2.2kVA 1.6kW.
Line Interactive UPS Tower Maintains regulated 230V nominal output without using battery power during brownouts and overvoltages from 151 to 282V. 2200VA power handling capability offers compatibility with a variety of networking, telecom and other sensitive electronic applications.
UPC Code |
037332120304 |
UPS Type |
Line-Interactive |
INPUT
Rated input current (Maximum Load) |
11.3A |
Nominal Input Voltage(s) Supported |
230V AC |
UPS Input Connection Type |
C20 inlet |
UPS Input Connection Description |
IEC320-C20 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles |
Input Phase |
Single-Phase |
OUTPUT
Output Volt Amp Capacity (VA) |
2200 |
Output kVA Capacity (kVA) |
2.20 |
Output Watt Capacity (Watts) |
1600 |
Output kW Capacity (kW) |
1.60 |
Power Factor |
0.7 |
Nominal Voltage Details |
230v inverter nominal output voltage |
Frequency Compatibility |
50 / 60 Hz |
Frequency Compatibility Details |
Automatic frequency selection |
Output Voltage Regulation (Line Mode) |
-19% +8% |
Output Voltage Regulation (Battery Mode) |
+/- 5% |
Included Output Power Cables |
Includes 3 C13 to C14 output power cables |
Load Management Receptacles |
Three switchable two-outlet C13 load banks |
Output Circuit Breakers |
10A (x2) - each breaker protects 4 C13 outlets each, C19 is unbreakered |
Hot-Swap PDU options |
PDUBHV20 (2U / 6 C13, 2 C19 outlets) |
Output AC Waveform (AC Mode) |
Sine wave |
Output AC Waveform (Battery Mode) |
PWM sine wave |
Nominal Output Voltage(s) Supported |
220V; 230V; 240V |
Output Receptacles |
(8) C13; (1) C19 |
Individually Controllable Load Banks |
Yes |
BATTERY
Battery Type |
Valve Regulated Lead Acid (VRLA) |
Full Load Runtime (min.) |
7 min. (1600w) |
Half Load Runtime (min.) |
19 min. (800w) |
Expandable Runtime |
No |
DC System Voltage (VDC) |
48 |
Battery Recharge Rate (Included Batteries) |
Less than 4 hours from 10% to 90% (typical, full load discharge) |
Battery Access |
Battery access door |
Internal UPS Replacement Battery Cartridge |
RBC54 |
Battery Replacement Description |
Hot-swappable, user replaceable batteries |
VOLTAGE REGULATION
Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151V to 282V |
Overvoltage Correction |
Input voltages between 245 and 282 are reduced by 12% |
Undervoltage Correction |
Input voltages between 177 and 199 are boosted by 14% |
Severe Undervoltage Correction |
Input voltages between 151 and 176 are boosted by 30% |
USER INTERFACE, ALERTS & CONTROLS
Switches |
2 Switches control off/on power status and alarm-cancel/self-test operation |
Alarm Cancel Operation |
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
Audible Alarm |
Audible alarm indicates power-failure, overload and low-battery conditions |
LED Indicators |
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating |
480 |
UPS AC Suppression Response Time |
Instantaneous |
EMI / RFI AC Noise Suppression |
Yes |
PHYSICAL
Cooling Method |
Fan |
Installation Form Factors Supported with Included Accessories |
Tower |
Primary Form Factor |
Tower |
Primary UPS Depth (mm) |
305 |
Primary UPS Height (mm) |
361 |
Primary UPS Width (mm) |
234 |
Shipping Dimensions (hwd / cm) |
49.02 x 38.61 x 40.39 |
Shipping Weight (kg) |
27.49 |
UPS Housing Material |
Polycarbonate |
UPS Power Module Dimensions (hwd, cm) |
36.07 x 23.37 x 30.48 |
UPS Power Module Weight (kg) |
24.49 |
ENVIRONMENTAL
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity |
0 to 95%, non-condensing |
AC Mode Efficiency Rating (100% Load) |
94% |
Audible Noise |
Audible Noise < 47dBA At Front Side 1 Meter |
COMMUNICATIONS
Network Management Cards |
SNMPWEBCARD ; TLNETCARD ; WEBCARDLX |
Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions; 2 USB ports, 1 DB9 serial and 1 DB9 contact closure port (4 total) |
PowerAlert Software |
For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert |
Communications Cable |
2 USB and 2 DB9 cables included |
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
Communications Interface |
Contact closure; DB9 Serial; Slot for SNMP/Web interface; USB |
LINE / BATTERY TRANSFER
Transfer Time |
2-4 milliseconds |
Low Voltage Transfer to Battery Power (Setpoint) |
151 |
High Voltage Transfer to Battery Power (Setpoint) |
282 |
SPECIAL FEATURES
Cold Start (Startup in Battery Mode During a Power Failure) |
Cold-start operation supported |
High Availability UPS Features |
Hot swappable batteries; Auto Probe Monitoring and Reboot (requires WEBCARDLX) |
STANDARDS & COMPLIANCE
UPS Certifications |
CE; Meets FCC Part 15 Category A (EMI) |
Certification Details |
CE 62040 |