TrippLite 2.2kVA SMX2200XLRT2U SmartPro 1.92kW Line-Interactive Rackmount UPS

by Tripplite

KES 94,000 Excl. Tax

TrippLite 2.2kVA SMX2200XLRT2U SmartPro 1.92kW Line-Interactive Rackmount UPS

  • 2.2kVA / 2200VA / 1920W line interactive 2U rack/tower UPS, Sine Wave
  • Extended runtime options up to 1600W, 0.9 Power Factor, Interactive LCD interface
  • 98% line-mode efficiency, 2 switched load banks, 4 post mounting kit
  • USB, RS232, EPO and slot for network management card options
  • 230V C20 inlet, 8 C13 outlets
  • To use the Auto Probe feature, this product requires a WEBCARDLX network interface (sold separately) running LX firmware update 15.5.2 or later
SKU16334

Reviews

This product does not have any reviews yet.

Add your review

Description

TrippLite 2.2kVA SMX2200XLRT2U SmartPro 1.92kW Line-Interactive Rackmount UPS 

TrippLite 2.2kVA SMX2200XLRT2U SmartPro 1.92kW Line-Interactive Rackmount UPS from the leading UPS dealer in Nairobi Kenya, buy online TrippLite 2.2kVA SMX2200XLRT2U SmartPro 1.92kW Line-Interactive Rackmount UPS and have it delivered.

 

Tripp Lite SmartPro Line Interactive UPS with enhanced LCD interface offers network-grade power protection for critical server, network and telecommunications equipment.

 

Tripp lite Line Interactive Uninterruptible Power Supply (UPS) with built-in Auto-Voltage Regulation (AVR) actively corrects brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure.

 

Tripp Lite's unique configuration excels in exceptionally poor-power environments with two separate levels of voltage boost to correct both slight undervoltages and severe brownout conditions.

OVERVIEW
UPC Code 037332124562
UPS Type Line-Interactive
INPUT
Rated input current (Maximum Load) 10.7A
Nominal Input Voltage(s) Supported 230V AC
UPS Input Connection Type C20 inlet
UPS Input Connection Description IEC320-C20 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles
Input Circuit Breakers 15A
Input Phase Single-Phase
OUTPUT
Output Volt Amp Capacity (VA) 2200
Output kVA Capacity (kVA) 2.20
Output Watt Capacity (Watts) 1920
Output kW Capacity (kW) 1.92
Power Factor 0.87
Nominal Voltage Details 230V nominal output in battery mode
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Automatic frequency selection
Output Voltage Regulation (Line Mode) -15%, +6%
Output Voltage Regulation (Battery Mode) +/- 5%
Included Output Power Cables Includes 3 C13 to C14 output power cables
Load Management Receptacles Two switchable single-outlet C13 load banks
Hot-Swap PDU options PDUBHV20 (2U / 6 C13, 2 C19 outlets)
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Nominal Output Voltage(s) Supported 220V; 230V; 240V
Output Receptacles (8) C13
Individually Controllable Load Banks Yes
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Full Load Runtime (min.) 5 min. (1920w)
Half Load Runtime (min.) 11.9 min. (960w)
Expandable Battery Runtime Extended runtime supported via optional external battery packs
Expandable Runtime Yes
External Battery Pack Compatibility  BP48V24-2U  (limit 1);  BP48V60RT-3U  (multi-pack compatible);  BP48V27-2US  (multi-pack compatible)
DC System Voltage (VDC) 48
Battery Recharge Rate (Included Batteries) Less than 4.5 hours from 10% to 90% (typical, full load discharge)
Battery Access Front panel battery access door
Internal UPS Replacement Battery Cartridge  RBC94-2U
Battery Replacement Description Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 158 to 278
Overvoltage Correction Voltage reduction of 12% applies when input is between 244-278V
Undervoltage Correction Voltage boost of 12% applies when input voltage is between 183-206V
Severe Undervoltage Correction Voltage boost of 24% applies when input voltage is between 158-182V
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
Switches 3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions
Alarm Cancel Operation Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
Audible Alarm Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 350
UPS AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
PHYSICAL
Cooling Method Fan
Included Mounting Accessory Description Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
Installation Form Factors Supported with Optional Accessories 2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )
Minimum Required Rack Depth with External Battery Pack (cm) 67
Minimum Required Rack Depth with External Battery Pack (in.) 26.5
Minimum Required Rack Depth without External Battery Pack (cm) 55
Minimum Required Rack Depth without External Battery Pack (in.) 21.75
Optional Mounting Accessory Notes Optional  2-9USTAND  enables upright tower UPS placement;  2POSTRMKITWM  enables wall-mount and 2-post rackmount installation;  4POSTRAILKITWM  enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm);  UPSHDEARKIT  enables installation in 2 or 4-post racks using front vertical rails only, without rear support
Primary Form Factor Rackmount
Primary UPS Depth (mm) 495
Primary UPS Height (mm) 89
Primary UPS Width (mm) 445
Rack Height 2U
Shipping Dimensions (hwd / cm) 22.10 x 61.47 x 54.61
Shipping Weight (kg) 36.76
UPS Housing Material Steel
UPS Power Module Dimensions (hwd, cm) 8.89 x 44.45 x 49.53
UPS Power Module Weight (kg) 31.18
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 161
AC Mode Efficiency Rating (100% Load) 98%
Audible Noise 45 dBA maximum, front side 1m
COMMUNICATIONS
Network Management Cards  SNMPWEBCARD ;  TLNETCARD ;  WEBCARDLX ;  RELAYIOCARD
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions
PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
Communications Cable USB, DB9 and EPO cabling included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
Communications Interface DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)
LINE / BATTERY TRANSFER
Transfer Time 6 ms. (AC to DC) / 1 ms. (DC to AC)
Low Voltage Transfer to Battery Power (Setpoint) 158V
High Voltage Transfer to Battery Power (Setpoint) 278V
SPECIAL FEATURES
Grounding Lug Back panel grounding lug
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Hot swappable batteries; Auto Probe Monitoring and Reboot (requires WEBCARDLX)
Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS; Individually controllable load banks
STANDARDS & COMPLIANCE
UPS Certifications CE
Certification Details IEC 62040-1, IEC 62040-2 Class A EMI, GOST