TrippLite 3kVA SMX3000XLRT2UA SmartPro 2.7kW Line-Interactive Rackmount UPS
TrippLite 3kVA SMX3000XLRT2UA SmartPro 2.7kW Line-Interactive Rackmount UPS from the leading UPS dealer in Nairobi Kenya, buy online TrippLite 3kVA SMX3000XLRT2UA SmartPro 2.7kW Line-Interactive Rackmount UPS and have it delivered.
Tripp Lite SmartPro Line Interactive UPS with enhanced LCD interface offers network-grade power protection for critical server, network and telecommunications equipment.
Line Interactive Uninterruptible Power Supply (UPS) with built-in Auto-Voltage Regulation (AVR) actively corrects brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure.
Tripp Lite's unique configuration excels in exceptionally poor-power environments with two separate levels of voltage boost to correct both slight undervoltages and severe brownout conditions.
UPC Code |
037332181381 |
UPS Type |
Line-Interactive |
INPUT
Rated input current (Maximum Load) |
14.1A |
Nominal Input Voltage(s) Supported |
230V AC |
UPS Input Connection Type |
C20 inlet |
UPS Input Connection Description |
IEC320-C20 input connection accepts a variety of user supplied detachable C19 output cordsets to match country or site specific power sources |
Input Circuit Breakers |
20A |
Input Phase |
Single-Phase |
OUTPUT
Output Volt Amp Capacity (VA) |
3000 |
Output kVA Capacity (kVA) |
3.00 |
Output Watt Capacity (Watts) |
2700 |
Output kW Capacity (kW) |
2.70 |
Power Factor |
0,9 |
Nominal Voltage Details |
230v nominal inverter output voltage |
Frequency Compatibility |
50 / 60 Hz |
Frequency Compatibility Details |
Automatic frequency selection |
Output Voltage Regulation (Line Mode) |
+6%, -15% |
Output Voltage Regulation (Battery Mode) |
+/-5% |
Included Output Power Cables |
Set of 3 C13 to C14 power cables included |
Load Management Receptacles |
Two switchable single outlet C13 load banks |
Output AC Waveform (AC Mode) |
Pure Sine wave |
Output AC Waveform (Battery Mode) |
Pure Sine wave |
Nominal Output Voltage(s) Supported |
220V; 230V; 240V |
Output Receptacles |
(8) C13; (1) C19 |
Individually Controllable Load Banks |
Yes |
BATTERY
Battery Type |
Valve Regulated Lead Acid (VRLA) |
Full Load Runtime (min.) |
3.9 min. (2700w) |
Half Load Runtime (min.) |
11.1 min. (1350w) |
Expandable Battery Runtime |
Extended runtime supported via optional external battery packs |
Expandable Runtime |
Yes |
External Battery Pack Compatibility |
BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible) |
DC System Voltage (VDC) |
48 |
Battery Recharge Rate (Included Batteries) |
Less than 5 hours from 10 to 90% (typical, full load discharge) |
Battery Access |
Front panel battery access door |
Internal UPS Replacement Battery Cartridge |
RBC58-2U |
Battery Replacement Description |
Hot-swappable, replaceable batteries |
VOLTAGE REGULATION
Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 158 to 278 |
Overvoltage Correction |
Input voltages between 244 and 278 are reduced by 12% |
Undervoltage Correction |
Input voltages between 206 and 183 are boosted by 12% |
Severe Undervoltage Correction |
Input voltages between 158 and 183 are boosted by 24% |
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display |
Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options) |
Switches |
3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions |
Alarm Cancel Operation |
Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available |
Audible Alarm |
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions |
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating |
350 |
EMI / RFI AC Noise Suppression |
Yes |
AC Suppression Response Time |
Instantaneous |
PHYSICAL
Cooling Method |
Fan |
Included Mounting Accessory Description |
Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm) |
Installation Form Factors Supported with Included Accessories |
4 post 19 inch rackmount |
Installation Form Factors Supported with Optional Accessories |
2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM ) |
Minimum Required Rack Depth with External Battery Pack (cm) |
67 |
Minimum Required Rack Depth with External Battery Pack (in.) |
26.5 |
Minimum Required Rack Depth without External Battery Pack (cm) |
58 |
Minimum Required Rack Depth without External Battery Pack (in.) |
23 |
Optional Mounting Accessory Notes |
Optional 2-9USTAND enables upright tower UPS placement; 2POSTRMKITWM enables wall-mount and 2-post rackmount installation; 4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm); UPSHDEARKIT enables installation in 2 or 4-post racks using front vertical rails only, without rear support |
Primary Form Factor |
Rackmount |
Primary UPS Depth (mm) |
495 |
Primary UPS Height (mm) |
89 |
Primary UPS Width (mm) |
445 |
Rack Height |
2U |
Shipping Dimensions (hwd / cm) |
22.86 x 60.32 x 52.07 |
Shipping Weight (kg) |
40.37 |
UPS Housing Material |
Steel |
UPS Power Module Dimensions (hwd, cm) |
8.89 x 44.45 x 49.53 |
UPS Power Module Weight (kg) |
28.49 |
ENVIRONMENTAL
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity |
0 to 95%, non-condensing |
AC Mode BTU / Hr. (Full Load) |
158 |
Battery Mode BTU / Hr. (Full Load) |
1501 |
AC Mode Efficiency Rating (100% Load) |
98% |
Audible Noise |
45 dBA maximum, front side 1m |
COMMUNICATIONS
Network Management Cards |
SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; RELAYIOCARD |
Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions |
PowerAlert Software |
For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert |
Communications Cable |
USB, DB9 and EPO cabling included |
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
Communications Interface |
DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) |
LINE / BATTERY TRANSFER
Transfer Time |
6 milliseconds (AC to battery mode), 1 millisecond (Battery to AC mode) |
Low Voltage Transfer to Battery Power (Setpoint) |
158 |
High Voltage Transfer to Battery Power (Setpoint) |
278 |
SPECIAL FEATURES
Cold Start (Startup in Battery Mode During a Power Failure) |
Cold-start operation supported |
High Availability UPS Features |
Hot swappable batteries; Auto Probe Monitoring and Reboot (requires WEBCARDLX) |
Green Energy-Saving Features |
Greater than 95% efficiency - GREEN UPS; Individually controllable load banks; Schedulable daily hours of economy mode operation |
STANDARDS & COMPLIANCE
UPS Certifications |
CE; ROHS (Restriction of Hazardous Substances) |
Certification Details |
IEC 62040-1, IEC 62040-2 Class A EMI, GOST |