APC Smart-UPS VT 40kVA 400V SUVTP40KH4B4S UPS Kenya
by Bosch
Brand: | APC by Schneider Electric |
Model Number: | SUVTP40KH4B4S |
Output Power Capacity: | 32kW / 40kVA |
Max Configurable Power: | 32kW / 40kVA |
Nominal Output Voltage: | 400V 3PH |
Topology: | Double Conversion Online |
Output Connections: | (1) Hard Wire 4-wire (3PH + G) (1) Hard Wire 5-wire (3PH + N + G) (1) Screw Terminals |
Bypass: | Built-in Maintenance Bypass Built-in Static Bypass |
Input Connections: | Hard Wire 5-wire (3PH + N + G) |
Includes: | Battery modules ship installed Bolt down brackets CD with software Installation guide Network Management Card Power modules ship installed Start up included User Manual |
Price: | Contact Sales |
SKU | 13078 |
---|
Reviews
Description
APC Smart-UPS VT 40kVA 400V SUVTP40KH4B4S UPS Kenya
APC Smart-UPS VT 40kVA 400V SUVTP40KH4B4S UPS Kenya Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
40kVA 400V SUVTP40KH4B4S UPS Gives higher application availability by correcting poor frequency and voltage conditions without using the battery. APC Smart-UPS VT 40kVA Enables pre-installation UPS staging and testing and faster installation.
APC Smart-UPS VT 40kVA Increases availability by allowing the UPS to be connected to two separate power sources. SUVTP40KH4B4S APC Smart-UPS VT 40kVA 400V w/4 Batt.
Mod., Start-Up 5X8, Internal Maint Bypass, Parallel Capability Battery modules ship installed , Bolt down brackets , CD with software , Installation guide , Network Management Card , Power modules ship installed , Start up included , User.
APC Smart-UPS VT 40kVA 400V w/4 Batt. Mod., Start-Up 5X8, Internal Maint Bypass, Parallel Capability
-
Parallel-capacity capableIncreases total power capacity by using multiple uninterruptible power supplies simultaneously.
-
Parallel-redundant capablePower the connected equipment with multiple uninterruptible power supplies to increase system redundancy
Smart-UPS VT Features & Benefits
Availability
-
Battery modules connected in parallelDelivers higher availability through redundant batteries.
-
Automatic internal bypassSupplies utility power to the connected loads in the event of a UPS power overload or fault.
-
Dual mains inputIncreases availability by allowing the UPS to be connected to two separate power sources.
-
Generator compatibleEnsures clean, uninterrupted power to protected equipment when generator power is used.
-
Scalable runtimeAllows additional run time to be quickly added as needed.
Manageability
-
Programmable frequencyEnsures compatibility with different input frequencies.
-
Audible alarmsProvides notification of changing utility power and UPS power conditions
-
LCD displayAlpha-Numeric Display which displays system parameters and alarms.
-
SmartSlotCustomize UPS capabilities with management cards.
-
InfraStruXure Manager CompatibleEnables centralized management via the APC InfraStruXure Manager.
-
Network manageableProvides remote power management of the UPS over the network.
-
LED status indicatorsQuickly understand unit and power status with visual indicators.
Total Cost of Ownership
-
Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.
-
Manual maintenance bypassReduces installation costs by eliminating the need for an external mechanical bypass.
-
Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.
-
Input power factor correctionMinimizes installation costs by enabling the use of smaller generators and cabling.
Sustainability
-
EU CoC for UPSEnsures that UPSs sold in the EU are highly efficient
Protection
-
Cold-start capableProvides temporary battery power when the utility power is out.
-
Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
-
Frequency and voltage regulationGives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Marketing Features
-
Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replaced
-
Input power factor correctionMinimizes installation costs by enabling the use of smaller generators and cabling.
-
Dual mains inputIncreases availability by allowing the UPS to be connected to two separate power sources.
-
Scalable runtimeAllows additional run time to be quickly added as needed.
-
Network manageableProvides remote power management of the UPS over the network.
-
Manual maintenance bypassReduces installation costs by eliminating the need for an external mechanical bypass.
Serviceability
-
Modular designProvides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
-
Battery replacement without toolsEnables fast battery replacement, lowering Mean Time to Repair (MTTR).
-
Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.
-
Shippable with modules installedEnables pre-installation UPS staging and testing and faster installation.
40kva UPS Battery Backup specifications
Output
- Output Power Capacity: 32.0 KW / 40.0 kVA
- Max Configurable Power (Watts): 32.0 KW / 40.0 kVA
- Nominal Output Voltage: 400V 3PH
- Output Voltage Note: Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
- Efficiency at Full Load: 95.8 %
- Output Voltage Distortion: Less than 5% at full load
- Output Frequency (sync to mains): 47 - 53 Hz for 50 Hz nominal
- Output Frequency (not synced): 50Hz +/- 0.1% for 50Hz nominal
- Other Output Voltages: 380, 415
- Crest Factor: 3 : 1
- Topology: Double Conversion Online
- Waveform Type: Sine wave
- Maximum Output Current: 64
- Bypass: Built-in Maintenance Bypass, Built-in Static Bypass
Input
- Nominal Input Voltage: 400V 3PH
- Input Frequency: 40- 70 Hz (auto sensing)
- Input Connections: Hard Wire 5-wire (3PH + N + G)
- Input voltage range for main operations: 304 - 477 V
- Other Input Voltages: 380 , 415
- Efficiency at Full Load: 95.8 %
- Maximum Input Current: 55 A
- Input Power Factor at Full Load: 0.98
Batteries & Runtime
- Battery Type: VRLA
- Included Battery Modules: 4
- Typical recharge time: 5 hour(s)
- Nominal Battery Voltage: +/-192 V (split battery referenced to neutral)
- Expected Battery Life (years): 3 - 5
- RBC Quantity: 4
- Extendable Run Time: 1
- End of Discharge Battery Voltage: +/-154 V
Communications & Management
- Interface Port(s): DB-9 RS-232, Smart-Slot
- Pre-Installed SmartSlot™ Cards: AP9631
- Control panel: Multi-function LCD status and control console
- Audible Alarm: Audible and visible alarms prioritized by severity
- Emergency Power Off (EPO): Yes
Physical
- Maximum Height: 1490.0 mm
- Maximum Width: 523.0 mm
- Maximum Depth: 842.0 mm
- Net Weight: 629.09kg