TrippLite 3kVA SMX3000XLRT2UA SmartPro 2.7kW Line-Interactive Rackmount UPSÂ
TrippLite 3kVA SMX3000XLRT2UA SmartPro 2.7kW Line-Interactive Rackmount UPS from the leading UPS dealer in Nairobi Kenya, buy online TrippLite 3kVA SMX3000XLRT2UA SmartPro 2.7kW Line-Interactive Rackmount UPS and have it delivered.
Â
Tripp Lite SmartPro Line Interactive UPS with enhanced LCD interface offers network-grade power protection for critical server, network and telecommunications equipment.
Line Interactive Uninterruptible Power Supply (UPS) with built-in Auto-Voltage Regulation (AVR) actively corrects brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure.
Â
Tripp Lite’s unique configuration excels in exceptionally poor-power environments with two separate levels of voltage boost to correct both slight undervoltages and severe brownout conditions.
| UPC Code | 037332181381 |
| UPS Type | Line-Interactive |
INPUT
| Rated input current (Maximum Load) | 14.1A |
| Nominal Input Voltage(s) Supported | 230V AC |
| UPS Input Connection Type | C20 inlet |
| UPS Input Connection Description | IEC320-C20 input connection accepts a variety of user supplied detachable C19 output cordsets to match country or site specific power sources |
| Input Circuit Breakers | 20A |
| Input Phase | Single-Phase |
OUTPUT
| Output Volt Amp Capacity (VA) | 3000 |
| Output kVA Capacity (kVA) | 3.00 |
| Output Watt Capacity (Watts) | 2700 |
| Output kW Capacity (kW) | 2.70 |
| Power Factor | 0,9 |
| Nominal Voltage Details | 230v nominal inverter output voltage |
| Frequency Compatibility | 50 / 60 Hz |
| Frequency Compatibility Details | Automatic frequency selection |
| Output Voltage Regulation (Line Mode) | +6%, -15% |
| Output Voltage Regulation (Battery Mode) | +/-5% |
| Included Output Power Cables | Set of 3 C13 to C14 power cables included |
| Load Management Receptacles | Two switchable single outlet C13 load banks |
| Output AC Waveform (AC Mode) | Pure Sine wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Nominal Output Voltage(s) Supported | 220V; 230V; 240V |
| Output Receptacles | (8) C13; (1) C19 |
| Individually Controllable Load Banks | Yes |
BATTERY
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Full Load Runtime (min.) | 3.9 min. (2700w) |
| Half Load Runtime (min.) | 11.1 min. (1350w) |
| Expandable Battery Runtime | Extended runtime supported via optional external battery packs |
| Expandable Runtime | Yes |
| External Battery Pack Compatibility | Â BP48V24-2UÂ (limit 1); Â BP48V60RT-3UÂ (multi-pack compatible); Â BP48V27-2USÂ (multi-pack compatible) |
| DC System Voltage (VDC) | 48 |
| Battery Recharge Rate (Included Batteries) | Less than 5 hours from 10 to 90% (typical, full load discharge) |
| Battery Access | Front panel battery access door |
| Internal UPS Replacement Battery Cartridge | Â RBC58-2U |
| Battery Replacement Description | Hot-swappable, replaceable batteries |
VOLTAGE REGULATION
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 158 to 278 |
| Overvoltage Correction | Input voltages between 244 and 278 are reduced by 12% |
| Undervoltage Correction | Input voltages between 206 and 183 are boosted by 12% |
| Severe Undervoltage Correction | Input voltages between 158 and 183 are boosted by 24% |
USER INTERFACE, ALERTS & CONTROLS
| Front Panel LCD Display | Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options) |
| Switches | 3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions |
| Alarm Cancel Operation | Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available |
| Audible Alarm | Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions |
SURGE / NOISE SUPPRESSION
| UPS AC Suppression Joule Rating | 350 |
| EMI / RFI AC Noise Suppression | Yes |
| AC Suppression Response Time | Instantaneous |
PHYSICAL
| Cooling Method | Fan |
| Included Mounting Accessory Description | Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm) |
| Installation Form Factors Supported with Included Accessories | 4 post 19 inch rackmount |
| Installation Form Factors Supported with Optional Accessories | 2 post rackmount (Â 2POSTRMKITWMÂ ); 2-4 post front rail rackmount (Â UPSHDEARKITÂ ); 4 post rackmount short-depth (Â 4POSTRAILKITWMÂ ); Tower (Â 2-9USTANDÂ ); Wallmount (Â 2POSTRMKITWMÂ ) |
| Minimum Required Rack Depth with External Battery Pack (cm) | 67 |
| Minimum Required Rack Depth with External Battery Pack (in.) | 26.5 |
| Minimum Required Rack Depth without External Battery Pack (cm) | 58 |
| Minimum Required Rack Depth without External Battery Pack (in.) | 23 |
| Optional Mounting Accessory Notes | Optional  2-9USTAND enables upright tower UPS placement;  2POSTRMKITWM enables wall-mount and 2-post rackmount installation;  4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm);  UPSHDEARKIT enables installation in 2 or 4-post racks using front vertical rails only, without rear support |
| Primary Form Factor | Rackmount |
| Primary UPS Depth (mm) | 495 |
| Primary UPS Height (mm) | 89 |
| Primary UPS Width (mm) | 445 |
| Rack Height | 2U |
| Shipping Dimensions (hwd / cm) | 22.86 x 60.32 x 52.07 |
| Shipping Weight (kg) | 40.37 |
| UPS Housing Material | Steel |
| UPS Power Module Dimensions (hwd, cm) | 8.89 x 44.45 x 49.53 |
| UPS Power Module Weight (kg) | 28.49 |
ENVIRONMENTAL
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Relative Humidity | 0 to 95%, non-condensing |
| AC Mode BTU / Hr. (Full Load) | 158 |
| Battery Mode BTU / Hr. (Full Load) | 1501 |
| AC Mode Efficiency Rating (100% Load) | 98% |
| Audible Noise | 45 dBA maximum, front side 1m |
COMMUNICATIONS
| Network Management Cards | Â SNMPWEBCARDÂ ; Â TLNETCARDÂ ; Â WEBCARDLXÂ ; Â RELAYIOCARD |
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
| PowerAlert Software | For local monitoring via the UPSÂ’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert |
| Communications Cable | USB, DB9 and EPO cabling included |
| WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
| Communications Interface | DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) |
LINE / BATTERY TRANSFER
| Transfer Time | 6 milliseconds (AC to battery mode), 1 millisecond (Battery to AC mode) |
| Low Voltage Transfer to Battery Power (Setpoint) | 158 |
| High Voltage Transfer to Battery Power (Setpoint) | 278 |
SPECIAL FEATURES
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| High Availability UPS Features | Hot swappable batteries; Auto Probe Monitoring and Reboot (requires WEBCARDLX) |
| Green Energy-Saving Features | Greater than 95% efficiency – GREEN UPS; Individually controllable load banks; Schedulable daily hours of economy mode operation |
STANDARDS & COMPLIANCE
| UPS Certifications | CE; ROHS (Restriction of Hazardous Substances) |
| Certification Details | IEC 62040-1, IEC 62040-2 Class A EMI, GOST |
Reviews