Description

Advanced Double-Conversion Architecture

The MPM 3K utilizes high-frequency double-conversion online topology for continuous power conditioning. This technology converts incoming AC power to DC, then regenerates clean AC output with precise voltage and frequency control. Consequently, connected equipment receives filtered power regardless of utility power quality variations.

Furthermore, the system operates with zero transfer time between utility and battery power modes. The online design eliminates switching delays that could disrupt critical systems. Therefore, servers, telecommunications equipment, and network infrastructure maintain uninterrupted operation during power transitions.

Enhanced Power Capacity and Efficiency

The Mercury MPM 3K provides 3000VA capacity with 2700W real power output through 0.9 power factor design. This configuration efficiently supports modern IT equipment with high power factor loads. Additionally, the system accommodates mixed loads including servers, workstations, and networking equipment simultaneously.

Real-time load monitoring displays power consumption through the integrated LCD interface. The MPM 3K also includes intelligent overload management with automatic bypass switching. Moreover, the system features thermal management and fan speed control for optimal efficiency across varying load conditions.

Extended Battery System and Runtime

The MPM 3K incorporates 8 x 7AH/12V sealed lead-acid batteries in 96VDC configuration. These maintenance-free batteries provide extended backup duration based on connected load requirements. Additionally, advanced battery management optimizes charging cycles and continuously monitors battery health status.

Smart charging technology employs multi-stage charging algorithms with temperature compensation. The system also features automatic battery testing to identify aging batteries before failure. Furthermore, optional external battery packs extend runtime for extended outage protection.

Comprehensive Input and Output Management

The Mercury MPM 3K operates across wide input voltage ranges to accommodate unstable utility conditions. Input voltage range spans 115VAC±5 to 295VAC±5 for loads ≤70%, and 160VAC±5 to 295VAC±5 for loads ≥70%. Additionally, the system handles frequency variations from 46-54Hz (50Hz) and 56-64Hz (60Hz) with automatic sensing.

Output voltage regulation maintains 220/230VAC ±2% accuracy under varying load conditions. The system provides pure sine wave output with <3% total harmonic distortion for compatibility with sensitive electronics. Moreover, frequency regulation ensures stable 50/60Hz ±0.2% output regardless of input frequency variations.

Advanced Communication and Monitoring

The MPM 3K includes RS232 and USB communication interfaces for comprehensive system monitoring and control. These connections enable integration with network management systems and SNMP monitoring software. Additionally, the system supports optional SNMP card installation for advanced enterprise network monitoring capabilities.

LCD display provides battery voltage display, load capacity display, and system status information. The interface shows real-time input/output voltages, load percentages, and battery status indicators. Furthermore, configurable alarms notify operators of system conditions requiring immediate attention.

Comprehensive Protection and Safety Systems

Multiple protection systems safeguard both the UPS and connected equipment from various power anomalies. The MPM 3K includes lightning and surge protection, short circuit and overload protection, and EMI/RFI noise filtering. Additionally, the system monitors input voltage anomalies and automatically compensates for power quality issues.

Emergency Power-Off (EPO) function provides instant UPS shutdown during emergencies. The system also features input line and neutral reversal detection with alarm functionality. Moreover, comprehensive thermal protection prevents overheating damage during high-load operation.

Flexible Installation and Environmental Adaptability

The Mercury MPM 3K supports tower installation with compact footprint requirements for office environments. The system operates efficiently with automatic fan speed control based on load and temperature conditions. Additionally, the MPM 3K accommodates various environmental conditions within specified operating parameters.

Fan speed auto control adjusts cooling based on load variations to minimize noise and extend component life. The system also includes dust filtration to maintain internal component cleanliness. Furthermore, the compact design facilitates installation in space-constrained server rooms and network closets.

Cold Start and Startup Capabilities

The MPM 3K features UPS startup without battery and cold start functionality. This capability allows system operation when batteries are disconnected or during initial commissioning. Additionally, the system supports generator input compatibility for backup power source integration.

Automatic battery charge in UPS off mode ensures batteries remain fully charged even when the UPS is powered down. The system also provides maintenance-free operation with sealed battery technology. Moreover, intelligent charging algorithms extend battery service life through optimized charge cycles.

Ideal Users

The Mercury MPM 3K Online UPS suits specific applications particularly well:

  • Medium data centers – True online double-conversion with zero transfer time protects server farms and storage systems
  • Network operations centers – 96VDC battery system with 8x7AH capacity provides extended runtime for critical networking infrastructure
  • Medical facilities – 0.9 power factor efficiency supports high-efficiency medical equipment while minimizing power consumption
  • Financial institutions – RS232/USB/SNMP communication enables comprehensive monitoring for regulatory compliance requirements
  • Manufacturing control systems – Wide input voltage range (115-295VAC) accommodates unstable industrial power conditions
  • Telecommunications providers – EMI/RFI filtering and surge protection ensure clean power for sensitive communication equipment

Power Specifications

  • Capacity: 3000VA / 2700W
  • Power Factor: 0.9 (leading/lagging)
  • Technology: True online double-conversion
  • Transfer Time: 0ms (continuous operation)
  • Efficiency: >90% at optimal load
  • Input Power Factor: ≥0.97

Input Characteristics

  • Voltage Range: 115VAC±5 to 295VAC±5 (load ≤70%), 160VAC±5 to 295VAC±5 (load ≥70%)
  • Frequency Range: 46-54Hz (50Hz)±0.5Hz, 56-64Hz (60Hz)±0.5Hz auto-sensing
  • Phase: Single phase with neutral and ground
  • Surge Protection: Built-in lightning and surge protection
  • EMI/RFI Filter: Integrated noise filtering

Output Performance

  • Voltage: 220/230VAC ±2%
  • Frequency: 50/60Hz ±0.2%
  • Waveform: Pure sine wave
  • Total Harmonic Distortion: <3% (linear load)
  • Voltage Regulation: ±2% (0-100% load)
  • Overload Capability: Multiple protection levels

Battery System

  • Configuration: 8 x 7AH/12V sealed lead-acid
  • DC Voltage: 96VDC nominal
  • Battery Life: 3-5 years (25°C ambient)
  • Charging Method: Smart multi-stage with temperature compensation
  • Battery Test: Automatic periodic testing
  • External Battery: Optional extension packs supported

Communication Interface

  • Standard Connections: RS232, USB
  • Optional: SNMP card slot
  • Monitoring Software: Compatible with standard UPS management
  • Remote Control: EPO (Emergency Power Off)
  • Display: LCD with voltage, load, and battery indicators
  • Alarms: Input reversal detection, fan malfunction

Physical Specifications

  • Form Factor: Tower design
  • Installation: Desktop or floor standing
  • Operating Temperature: 0°C to 40°C
  • Storage Temperature: -15°C to 45°C
  • Relative Humidity: 0-95% non-condensing
  • Cooling: Automatic fan speed control

Protection Features

  • Overload Protection: Automatic bypass and load shedding
  • Short Circuit Protection: Output and battery circuits
  • Over-temperature Protection: Thermal shutdown with alarm
  • Battery Protection: Over/under voltage, over-current
  • Input Protection: Surge, lightning, and brownout protection
  • Network Protection: Fax/modem surge protection ports