Mecer 10KVA 3 Phase Online Smart UPS
Mecer 10KVA 3 Phase Online Smart UPS from the leading mecer UPS dealer in Nairobi Kenya, buy online and have it delivered, 10KVA 3 Phase Online Smart UPS.
Mecer 10KVA 3 Phase Online UPS is a high frequency unit specifically designed for servers, data-center critical network devices, sensitive electronic equipment, telecom, banks, hospitals etc.
| SKU | ME-3000-WPTU |
|---|---|
| WEIGHT | 27.600 |
| PHYSICAL DIMENSIONS | 421 x 190 x 318 (mm) |
| CAPACITY | 3000 VA / 2400 W |
| VOLTAGE RANGE LOW LINE TRANSFER | 160VAC/140VAC/120VAC/110VAC±5% ( based on load percentage 100% – 80 % / 80 % – 70 % / 70 – 60 % / 60 % – 0) |
| VOLTAGE RANGE LOW LINE COMEBACK | 168VAC/148VAC/128VAC/118VAC ± 5 % ( based on load percentage 100% – 80 % / 80 % – 70 % / 70 – 60 % / 60 % – 0) |
| VOLTAGE RANGE HIGH LINE TRANSFER | 300 VAC ± 5 % |
| VOLTAGE RANGE HIGH LINE COMEBACK | 290 VAC ± 5 % |
| FREQUENCY RANGE | 40Hz ~ 70 Hz |
| PHASE | Single phase with ground |
| POWER FACTOR | ? 0.99 @ nominal voltage (input voltage) |
| OUTPUT VOLTAGE | 200/208/220/230/240VAC |
| AC VOLTAGE REGULATION (BATT. MODE) | ±1% (Batt. Mode) |
| FREQUENCY RANGE (SYNCHRONIZED RANGE) | 47 ~ 53 Hz or 57 ~ 63 Hz |
| FREQUENCY RANGE (BATT. MODE) | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz |
| OVERLOAD | Sounding twice every second |
| CURRENT CREST RATIO | 3:1 |
| HARMONIC DISTORTION | ? 3 % THD (linear load) ? 6 % THD (non-linear load) |
| WAVEFORM (BATT. MODE) | Pure Sinewave |
| AC TO DC | Zero |
| INVERTER TO BYPASS | 4 ms (Typical) |
| AC MODE | 90% |
| BATTERY MODE | 88% |
| BATTERY TYPE | 12 V / 9 AH |
| NUMBERS | 6 |
| RECHARGE TIME | 4 hours recover to 90% capacity (Typical) |
| CHARGING CURRENT | 1.0 A (max.) |
| CHARGING VOLTAGE | 82.1 VDC ± 1% |
| BATTERY TYPE & NUMBERS | No |
| CHARGING CURRENT | No |
| CHARGING VOLTAGE | No |
| HUMIDITY | 20-90 % RH @ 0- 40°C (non-condensing) |
| NOISE LEVEL | Less than 50dBA @ 1 Meter |
| OPTIONAL USB/RS-232 PORT | Supports Windows® 2000/2003/XP/Vista/2008/7, Linux, Unix and MAC |
| OPTIONAL SNMP | Power management from SNMP manager and web browser |
Run-times of ME-3000-WPTU 3kVA
| Model | Number of Batteries | Encasement | 100% Load Backup Time | 75% Load Backup Time | 50% Load Backup Time | 25% Load Backup Time |
| ME-3000-WPTU | 6 | Internal | 4.5 Minutes | 7 Minutes | 13 Minutes | 31 Minutes |
• Online-Double conversion • Supports all kinds of load, high overload capability • Fully digitally controlled with 3 DSP’s for IGBT rectifier, inverter and battery charger • Digital Circulating Current Control Technology, Increasing Parallel Reliability • Green Power Technology, High Input Power Factor, Low Current THD, High Efficiency • Intellegent self-diagnosis function, All kinds of fault protection, Large event log capability • Redundant Design of Power Model Fans, Increasing system reliability • High MTBF (Mean Time Between Failures) (>200,000 HOURS), Low MTTR (Mean Time To Repair












Reviews
There are no reviews yet.