General Overview:
- Type: Fire Alarm Control Panels (FACP)
- Purpose: To detect, monitor, and signal alarms in case of fire or smoke in buildings or facilities.
- Compatibility: Designed to work with various detection devices, including smoke detectors, heat detectors, manual call points, and alarms.
System Configuration:
- Zones: Available in various configurations (e.g., 1 zone, 2 zones, 4 zones, 8 zones, 16 zones, etc.)
- Addressable/Conventional: Can be either conventional (grouped detection devices) or addressable (each device has a unique address).
- Panel Capacity: Range from small, localized systems to large, integrated systems with multiple zones.
Key Features:
Detection Devices Supported:
- Smoke Detectors
- Heat Detectors
- Manual Call Points
- Gas Detection Sensors
- Flame Detectors
Status Indicators:
- LED Display for zone status (Normal, Alarm, Fault, Trouble)
- LCD Display: In some models, large screen LCD for easy event viewing, fault indications, and system status.
Control Features:
- Alarm Output: Audible and visual alarms, typically through horns, bells, or strobe lights.
- Manual Reset: Option to manually reset the system after an alarm event.
- Test Function: Built-in test function for each zone and device.
- Silence Alarm: Ability to mute the alarm while maintaining system monitoring.
- Bypass Mode: Option to bypass a faulty zone for maintenance without triggering false alarms.
Inputs/Outputs:
- Inputs:
- Multiple zones for fire alarm monitoring.
- External Inputs: Integration with emergency lighting, fire doors, or fire suppression systems.
- Outputs:
- Relay Outputs: For controlling external devices (e.g., fire suppression systems, elevators, ventilation control).
- Auxiliary Outputs: Additional outputs for third-party devices or monitoring.
- Communication Outputs: RS-485 or Ethernet ports for communication with external systems or monitoring centers.
Power & Battery:
- Input Voltage: Typically 110V - 240V AC (depending on region).
- Backup Power: 12V DC rechargeable battery for emergency operation in case of power failure.
- Battery Capacity: Sufficient to maintain operation for 24-48 hours during power failure, depending on panel model and load.
- Battery Charging Circuit: Built-in charger for efficient battery maintenance and monitoring.
Connectivity & Integration:
- Networking: Ability to network multiple panels for large or multi-building setups, including monitoring and control.
- Remote Monitoring: Optional modules or built-in functionality for remote monitoring via Ethernet, Wi-Fi, or GPRS.
- Integration with Fire Suppression Systems: Capable of integrating with fire suppression systems such as sprinklers, gas-based suppression, and emergency shutdown systems.
Alarms & Notifications:
- Visual Indicators: LED lights or digital displays to show the status of the system (Normal, Alarm, Fault).
- Audible Indicators: Built-in siren, bells, or optional connection to external sounders.
- Event Log: Records and stores historical alarm events (up to 500 or more), including time stamps for each event for troubleshooting and audits.
Design & Enclosure:
- Mounting: Wall-mounted or panel-mounted depending on system design.
- Enclosure: Durable metal or ABS plastic enclosures, often with IP rating for environmental protection (IP54, IP65).
- Size: Compact and scalable to suit different building sizes, with expandable modules in larger systems.
- Security: Optional lockable enclosures to prevent unauthorized access.
Sku: 9122Fire Alarm Panels systems
KSh 25,000Original price was: KSh 25,000.KSh 24,000Current price is: KSh 24,000. ( Ex VAT )KSh 25,000Original price was: KSh 25,000.KSh 24,000Current price is: KSh 24,000. ( Ex VAT ) Add to cart - -5%
General Features:
- Cable Type: Fire-resistant, low smoke zero halogen (LSZH) cable
- Conductor Size: 1.5mm²
- Number of Cores: 2-core or multi-core options available
- Standard Compliance: Certified to BS EN 50200, BS 7629-1, and BS 6387
Conductor:
- Material: Plain annealed stranded copper
- Nominal Cross-Sectional Area: 1.5mm²
Insulation:
- Material: Insulated with high-performance fire-resistant material
- Thermal Stability: Maintains performance at elevated temperatures
Sheath:
- Material: LSZH outer sheath for reduced smoke and toxic emissions
- Color: Red for fire safety applications
Performance:
- Fire Resistance Ratings:
- PH30 or PH120 (depending on installation)
- Withstands 950°C for up to 3 hours
- Temperature Range: -25°C to +90°C
- Voltage Rating: 300/500V
- Smoke and Toxicity: Produces minimal smoke and toxic gases during a fire
Mechanical Properties:
- Minimum Bending Radius: 6x the cable diameter
- Impact Resistance: Durable design to withstand physical stress
Applications:
- Primary Use: Fire alarm systems, emergency lighting, and voice alarm systems
- Other Uses: Suitable for public buildings, offices, hospitals, and high-risk areas requiring fire safety
Sku: 9119FP200 Gold Prysmian 1.5mm Fire Resistant Alarm Cable
KSh 29,000Original price was: KSh 29,000.KSh 27,500Current price is: KSh 27,500. ( Ex VAT )KSh 29,000Original price was: KSh 29,000.KSh 27,500Current price is: KSh 27,500. ( Ex VAT ) Add to cart - -4%
- Model: AW-CFP2166-2
- Type: 2 Zone Fire Alarm Control Panel
- Brand: Asenware
General Features:
Power Supply:
- Input Voltage: 220V AC (50/60Hz)
- Backup Battery: 12V DC, with capacity for sealed lead-acid battery (optional)
- Power Consumption: Low power consumption with energy-efficient design
Display:
- LED Display: Clear and easy-to-read LED indicator lights for zone status
- Status Indicators: Indicators for Normal, Alarm, Fault, and Trouble conditions
Zone Capacity:
- Zones: 2 independent alarm zones for customized fire detection coverage
- Detector Compatibility: Compatible with conventional detectors (smoke, heat, or combined detectors)
Alarm System:
- Alarm Output: Integrated horn or bell alarm output for notification
- Alarm Signal Type: Audible and visual alarm signals
- Alarm Mode: Continuous alarm in event of fire detection or fault
- Alarm Volume Control: Adjustable alarm volume to meet installation needs
Input & Output:
- Inputs: 2 alarm zones with individual monitoring for each zone
- Outputs: Includes relay outputs for control of external devices (e.g., fire doors, ventilation systems)
- Auxiliary Outputs: Optional outputs for fire pump activation, control systems, and external signaling
Control Features:
- Manual Reset: Manual reset functionality after alarm activation
- Test Function: Built-in test button for system maintenance
- Fault Indicators: Continuous monitoring for power failure, wiring faults, or detector issues
- Silence Alarm: Mute alarm temporarily after event without resetting the system
- Bypass Function: Option to bypass a zone in maintenance mode
Communication:
- Remote Monitoring: Optional communication modules for remote monitoring or integration with a central monitoring system
- Serial Port: Optional RS-485 or Ethernet connection for integration with other devices
- Network Compatibility: Can be connected to centralized fire alarm systems or extended networks
Design and Build:
- Enclosure: Compact, metal enclosure for durability and ease of installation
- Mounting: Designed for wall-mounted installation
- Dimensions: 300mm x 250mm x 80mm (H x W x D), compact for space-saving installations
- Weight: Approximately 2.5 kg (without battery)
Power and Battery:
- Power Supply Voltage: 220V AC
- Backup Battery: Typically 12V DC, with optional battery for backup power
- Battery Charging: Built-in charging circuit for efficient battery charging and maintenance
Certifications & Compliance:
- Compliance: Meets industry standards, such as EN 54-2 (Fire Detection and Alarm Systems), ISO 9001 for quality management
- Approval: Certified to comply with local regulations for fire safety and alarm systems
Sku: 91162 Zone Fire Alarm Control Panel AW-CFP2166-2 Asenware
KSh 28,000Original price was: KSh 28,000.KSh 27,000Current price is: KSh 27,000. ( Ex VAT )KSh 28,000Original price was: KSh 28,000.KSh 27,000Current price is: KSh 27,000. ( Ex VAT ) Add to cart - -25%
General Overview:
- Type: Manual Break Glass Fire Alarm
- Purpose: To manually trigger the fire alarm system by breaking the glass and activating the alarm.
Key Features:
- Activation Mechanism:
- Glass Element: Breakable glass panel to trigger alarm when pushed or broken.
- Push Button Option: Some models may feature a push button for manual activation without breaking glass.
- Alarm Triggering:
- Direct Connection to fire alarm control panel to send an immediate alarm signal.
- Latching Mechanism: Often designed with a latch that requires resetting after activation.
Design & Material:
- Housing Material:
- Typically ABS plastic or metal for durability.
- Weatherproof Options available for outdoor use or in areas exposed to harsh conditions.
- Glass Panel: Toughened glass that is easy to break when required but resistant to casual damage.
- Size: Compact design for easy wall mounting, typically measuring around 4-6 inches in height and width.
- Color: Commonly red, with clear glass for visibility.
Mounting & Installation:
- Mounting Type: Wall-mounted; standard flush or surface-mounted.
- Mounting Height: Typically installed at a height of 1.2m - 1.5m from the ground for easy access.
- Reset Mechanism: Can be reset manually after activation, often requiring a key or tool to reset.
Electrical Specifications:
- Voltage Rating: Compatible with most fire alarm control panels operating at 12V DC or 24V DC.
- Current Rating: Low current consumption for minimal impact on the alarm panel’s power supply.
- Wiring Type: Typically 2-wire or 4-wire configurations for connection to the fire alarm panel.
Indicators:
- Status LED: Built-in LED light (green or red) indicating whether the break glass unit is in normal (safe) or activated (alarm) mode.
- Visibility: Clear marking with "FIRE" or "ALARM" text and instructions to ensure immediate understanding during an emergency.
Compliance & Standards:
- Certifications:
- Complies with global safety standards such as EN 54, UL 38, and other fire safety regulations.
- Some models may have IP rating (e.g., IP44, IP65) for protection against dust and moisture.
Maintenance & Service:
- Regular Testing: Must be periodically tested to ensure proper activation.
- Glass Replacement: Easy to replace the glass after activation, reducing downtime after an alarm event.
- Durability: Long-lasting, robust design requiring minimal maintenance once installed correctly.
Sku: 9114Manual Fire Alarm Break Glass
KSh 2,000Original price was: KSh 2,000.KSh 1,500Current price is: KSh 1,500. ( Ex VAT )KSh 2,000Original price was: KSh 2,000.KSh 1,500Current price is: KSh 1,500. ( Ex VAT ) Add to cart